| | | | relay plate and relaysfuse holderOnboard supply control unitFastenersflat contact housing mounting | | relay plate and relaysfuse holderOnboard supply control unitFastenersflat contact housing mounting | | | |
| | | | Fuse socket | | Fuse socket | | | |
| | 1 | | Fuse socket see illustration: | | Fuse socket see illustration: | 915-000 | | |
| | 1 | | Fuse socket see illustration: | | Fuse socket see illustration: | 915-010 | | |
| | 2 | | See item: | | See item: | 1 | | |
| | 3 | | See item: | | See item: | 1 | | |
| | 4 | | See item: | | See item: | 1 | | |
| | 5 | | See item: | | See item: | 1 | | |
| | 6 | | See item: | | See item: | 1 | | |
| | | | relay plate and relays | | relay plate and relays | | | |
| | 10 | 6Q0 972 595 A | 6Q0 972 595 A qty: 1 relay plate | | relay plate | | 1 | |
| | (10) | 3C0 951 253 A | 3C0 951 253 A qty: 1 Relay | | Relay | | 1 | |
| | 11 | 4H0 951 253 | 4H0 951 253 qty: 1 RelayAir pump relay location/code no.: to be used for code no.: | | RelayAir pump relay location/code no.: to be used for code no.: | 1/644 100 | 1 | |
| | (11) | 191 906 383 C | 191 906 383 C qty: 1 contact close relay | | contact close relay | | 1 | |
| | (11) | 1J0 906 381 A | 1J0 906 381 A qty: 1 Relay relay location/code no.: | | Relay relay location/code no.: | /109 | 1 | |
| | (11) | 4H0 951 253 A | 4H0 951 253 A qty: 1 Relay relay location/code no.: to be used for code no.: | | Relay relay location/code no.: to be used for code no.: | 40A /645 53+373 | 1 | |
| | (11) | 4H0 951 253 A | 4H0 951 253 A qty: 1 Relay relay location/code no.: to be used for code no.: | | Relay relay location/code no.: to be used for code no.: | /645 18 | 1 | |
| | (11) | 4H0 951 253 C | 4H0 951 253 C qty: 1 Relay relay location/code no.: to be used for code no.: | | Relay relay location/code no.: to be used for code no.: | 12/646 404 | 1 | |
| | (11) | 4H0 951 253 A | 4H0 951 253 A qty: 1 Relayfor fuel pump relay location/code no.: to be used for code no.: | | Relayfor fuel pump relay location/code no.: to be used for code no.: | 13/645 53+643 | 1 | |
| | (11) | 4H0 951 253 A | 4H0 951 253 A qty: 1 Relay relay location/code no.: to be used for code no.: | | Relay relay location/code no.: to be used for code no.: | 40A 15/645 53+373+643 | 1 | |
| | (11) | 4H0 951 253 A | 4H0 951 253 A qty: 1 RelayLocking unit relay location/code no.: to be used for code no.: | | RelayLocking unit relay location/code no.: to be used for code no.: | 40A 15/645 53+447+643 | 1 | |
| | | | Onboard supply control unit | | Onboard supply control unit | | | |
| | 12 | | Onboard supply control unit see illustration: | | Onboard supply control unit see illustration: | 937-050 | | |
| | | | Fastenersflat contact housing mounting | | Fastenersflat contact housing mounting | | | |
| | 13 | 6Q2 907 371 D | 6Q2 907 371 D qty: 1 Bracket for relay carrier andonboard power supply CU | | Bracket for relay carrier andonboard power supply CU | | 1 | |
| | 14 | 6Q0 937 403 A | 6Q0 937 403 A qty: 1 flat contact housing mounting | | flat contact housing mounting | | 1 | |
| | 15 | 6Q0 971 615 A | 6Q0 971 615 A qty: 1 Cable holder | | Cable holder | | 1 | |
| | 18 | 6Q0 937 513 | 6Q0 937 513 qty: 1 Potential distributor | | Potential distributor | | 1 | |
| | 19 | N90 215 805 | N90 215 805 qty: 4 Hexagon collar nut | | Hexagon collar nut | M6 | 4 | |
| | 20 | N90 771 603 | N90 771 603 qty: 1 Socket head bolt with hexagonsocket head (combination) | | Socket head bolt with hexagonsocket head (combination) | M6X20 | 1 | |
| | 21 | 191 937 501 | 191 937 501 qty: 1 bracket for thermo switch | | bracket for thermo switch | | 1 | |
| | 22 | 443 937 105 | 443 937 105 qty: 1 Thermal fuse | | Thermal fuse | 20A | 1 | |
| | (22) | 443 937 105 A | 443 937 105 A qty: 1 Thermal fuse | | Thermal fuse | 30A | 1 | |
| | 23 | 1H0 937 083 | 1H0 937 083 qty: 1 BracketTrim for centralelectrics | | BracketTrim for centralelectrics | | 1 | |
| | | | fuse holder | | fuse holder | | | |
| | 25 | 6Q0 941 828 C | 6Q0 941 828 C qty: 1 fuse holder | | fuse holder | | 1 | |
| | 26 | 6Q0 998 824 | 6Q0 998 824 qty: 1 Jumper | | Jumper | 5 point | 1 | |
| | 27 | N01 713 112 | N01 713 112 qty: 1 flat fuse 19/2x5 | | flat fuse 19/2x5 | 15A -lt blue- | 1 | |
| | (27) | N01 713 123 | N01 713 123 qty: 1 flat fuse 19/2x5 | | flat fuse 19/2x5 | 20A -yellow- | 1 | |
| | (27) | N01 713 114 | N01 713 114 qty: 1 flat fuse 19/2x5 | | flat fuse 19/2x5 | 25A -cl.glass- | 1 | |
| | (27) | N01 713 125 | N01 713 125 qty: 1 flat fuse 19/2x5 | | flat fuse 19/2x5 | 30A-lt green- | 1 | |
| | (27) | N01 713 120 | N01 713 120 qty: 1 flat fuse 19/2x5 | | flat fuse 19/2x5 | 40A -orange- | 1 | |
| | 28 | N10 261 502 | N10 261 502 qty: 1 flat fuse 10/2x2, 8 | | flat fuse 10/2x2, 8 | 7.5A -brown- | 1 | |
| | (28) | N10 261 503 | N10 261 503 qty: 1 flat fuse 10/2x2, 8 | | flat fuse 10/2x2, 8 | 10A -red- | 1 | |
| | (28) | 8L0 998 131 | 8L0 998 131 qty: 11 1 set of flat fuses | | 1 set of flat fuses | | 11 | |
| | 29 | 8D0 941 802 | 8D0 941 802 qty: 1 Assembly tool for bladefuse | | Assembly tool for bladefuse | | 1 | |
| | 35 | 1J0 919 506 M | 1J0 919 506 M qty: 1 Control unit for radiatorfan see illustration, item: | | Control unit for radiatorfan see illustration, item: | 959-050, 13 | 1 | |
| | 37 | 3B0 951 253 | 3B0 951 253 qty: 1 contact close relayfor vehicles with additionalcoolant pump | | contact close relayfor vehicles with additionalcoolant pump | | 1 | |