| | | | Wire setfor models with supplementaryheater | | Wire setfor models with supplementaryheater | WEBASTO | | |
| | | | ------------------------------Also note the overview forDIY wiring sets------------------------------ | | ------------------------------Also note the overview forDIY wiring sets------------------------------ | | | |
| | (1) | 251 971 083 N | 251 971 083 N qty: || || || 1 Wire setfor models with supplementaryheater F 24-L-000 001>> | | Wire setfor models with supplementaryheater F 24-L-000 001>> | | || || || 1 | |
| | (1) | 251 971 083 M | 251 971 083 M qty: || || || 1 Wire setfor models with supplementaryheater F 24-L-000 001>> diesel eng. | | Wire setfor models with supplementaryheater F 24-L-000 001>> | | || || || 1 | diesel eng. |
| | 2 | 251 972 237 C | 251 972 237 C qty: 1 Wire setGlow plug | | Wire setGlow plug | for: | 1 | |
| | 3 | N01 712 11 | N01 712 11 qty: 1 Safety fuse | | Safety fuse | a8 white | 1 | |
| | 4 | N01 712 14 | N01 712 14 qty: 1 fuse | | fuse | a16 red | 1 | |
| | 5 | 171 937 501 | 171 937 501 qty: 1 Fuse socket | | Fuse socket | 2 point | 1 | |
| | 6 | 135 937 501 A | 135 937 501 A qty: || 1 relay plate F 24-G-000 001>> 24-K-175 000 diesel eng. | | relay plate F 24-G-000 001>> 24-K-175 000 | 9 pin | || 1 | diesel eng. |
| | 7 | N90 666 101 | N90 666 101 qty: || 2 Cable ties F 24-G-000 001>> | | Cable ties F 24-G-000 001>> | 4, 6X200 | || 2 | |
| | 8 | 803 971 831 | 803 971 831 qty: 1 Flat contact housing | | Flat contact housing | 6 pin | 1 | |
| | 9 | 803 971 833 A | 803 971 833 A qty: 1 flat connector housing | | flat connector housing | 6 pin | 1 | |
| | (10) | N90 666 101 | N90 666 101 qty: 1 Cable ties | | Cable ties | 4, 6X200 | 1 | |
| | 11 | 443 971 867 | 443 971 867 qty: 2 Grommetthermal switch diesel eng. | | Grommetthermal switch | 8, 5 | 2 | diesel eng. |
| | - | 191 919 231 | 191 919 231 qty: || || 1 Flat contact housingthermal switch F 24-G-000 001>> 24-K-175 000 | | Flat contact housingthermal switch F 24-G-000 001>> 24-K-175 000 | 2 pin | || || 1 | |
| | - | 037 906 240 | 037 906 240 qty: || || || 1 flat contact housing withgasketthermal switch F 24-L-000 001>> | | flat contact housing withgasketthermal switch F 24-L-000 001>> | 2 pin | || || || 1 | |
| | (11) | 191 919 459 | 191 919 459 qty: || || 1 Protective capthermal switch F 24-G-000 001>> 24-K-175 000 | | Protective capthermal switch F 24-G-000 001>> 24-K-175 000 | | || || 1 | |
| | (11) | 357 972 741 A | 357 972 741 A qty: || || || || 2 single wiring seal for wire cross section:thermal switch F 24-L-000 001>> | | single wiring seal for wire cross section:thermal switch F 24-L-000 001>> | red 1, 5 | || || || || 2 | |
| | 12 | 251 971 878 | 251 971 878 qty: 1 Grommet | | Grommet | 19 | 1 | |
| | 13 | 111 971 921 B | 111 971 921 B qty: 3 Flat contact housing | | Flat contact housing | 1 pin | 3 | |
| | 14 | 2D0 971 989 C A | 2D0 971 989 C A qty: 1 Flat contact housing | | Flat contact housing | 8 pin | 1 | |
| | 15 | 161 971 976 A | 161 971 976 A qty: 1 flat connector housing | | flat connector housing | 1 pin | 1 | |
| | 16 | 161 971 988 C | 161 971 988 C qty: || 1 flat connector housing F 24-G-000 001>> | | flat connector housing F 24-G-000 001>> | 2 pin | || 1 | |
| | 17 | 161 971 989 C | 161 971 989 C qty: 1 Flat contact housing | | Flat contact housing | 2 pin | 1 | |
| | (18) | 111 971 921 B | 111 971 921 B qty: 2 Flat contact housing | | Flat contact housing | 1 pin | 2 | |
| | - | 161 971 990 A | 161 971 990 A qty: || 1 Flat contact housing F 24-G-000 001>> | | Flat contact housing F 24-G-000 001>> | 1 pin | || 1 | |