Fanheat exchangerAir guide channel heater - Transporter(TR) [EUROPA 1998 year]

Fanheat exchangerAir guide channel heater - Transporter - tr
â„– part number information description remark unit model
Fanheat exchangerAir guide channel
Fanheat exchangerAir guide channel heater
2   701 819 019    701 819 019 qty: 1
Seal
  Seal 1
(3)   701 819 021 B    701 819 021 B qty: 1
Fan
  Fan lhd 1
(3)   702 819 021 A    702 819 021 A qty: 1
Fan
  Fan rhd 1
4   701 819 031 A    701 819 031 A qty: 1
heat exchanger
  heat exchanger lhd 1
(4)   702 819 031 A    702 819 031 A qty: 1
heat exchanger
  heat exchanger rhd 1
4A   7D0 819 069    7D0 819 069 qty: 1
Seal
  Seal 810X25X6 1
(5)   7D1 819 043    7D1 819 043 qty: 1
Air guide channel
  Air guide channel lhd 1
(5)   702 819 043 B    702 819 043 B qty: 1
Air guide channel
  Air guide channel rhd 1
5A   701 815 083 A    701 815 083 A qty: 1
Damping
ACV
  Damping lhd 1 ACV
(5A)   702 815 083    702 815 083 qty: 1
Damping
ACV
  Damping rhd 1 ACV
6   701 819 063    701 819 063 qty: 1
Intermediate piece
  Intermediate piece lhd 1
(6)   702 819 063    702 819 063 qty: 1
Intermediate piece
  Intermediate piece rhd 1
7   701 819 070    701 819 070 qty: 1
Seal
  Seal 1
12A   7D1 820 153    7D1 820 153 qty: || || || 1
Intake ductfor recirculated air operationpossibility F >> 70-W-095 695
  Intake ductfor recirculated air operationpossibility F >> 70-W-095 695 lhd || || || 1
(12A)   7D1 820 153 A    7D1 820 153 A qty: || || || 1
Intake ductfor recirculated air operationpossibility F 70-W-095 696>>
  Intake ductfor recirculated air operationpossibility F 70-W-095 696>> lhd || || || 1
(12A)   7D2 820 153    7D2 820 153 qty: 1
Intake ductfor recirculated air operationpossibility
  Intake ductfor recirculated air operationpossibility rhd 1
(13)   701 819 164 A    701 819 164 A qty: 1
Cover
  Cover 142, 9X128, 4MM 1
14   321 819 059    321 819 059 qty: X
Clip
  Clip X
(15)   702 819 351 A    702 819 351 A qty: 1
Air distribution housing
  Air distribution housing rhd 1
16   191 819 598    191 819 598 qty: 1
Bungs
  Bungs 1
16A   155 853 149    155 853 149 qty: 1
oval head panel screw
  oval head panel screw H5X17 1
18   N01 021 86    N01 021 86 qty: 2
Hexagon bolt
  Hexagon bolt M6X25 2
20   N01 166 53    N01 166 53 qty: 3
Washer
  Washer 5, 3X15X1, 6 3
22   N01 396 81    N01 396 81 qty: 3
oval head panel screw
  oval head panel screw 4, 8X13 3
23   N90 168 604    N90 168 604 qty: 3
Speed nut
  Speed nut M6X23, 4X16 3
(24)   1H0 820 119 A    1H0 820 119 A qty: 1
Water drain valve
  Water drain valve rhd 1
25   357 819 465    357 819 465 qty: 2
Vent trim
  Vent trim 2
26   321 819 017    321 819 017 qty: 2
Seal
  Seal 680X8X10 2
(27)   703 819 485 A    703 819 485 A qty: 2
Cover cap
  Cover cap 2
(28)   701 819 994    701 819 994 qty: 1
water drain pipe
  water drain pipe rhd 1
29   028 906 283    028 906 283 qty: || || || 1
Solenoid valvefor recirculated air operationpossibility F >> 70-W-095 695
  Solenoid valvefor recirculated air operationpossibility F >> 70-W-095 695 lhd || || || 1
29   028 906 283    028 906 283 qty: || || || 1
Solenoid valvefor recirculated air operationpossibility F 70-W-095 695>>
  Solenoid valvefor recirculated air operationpossibility F 70-W-095 695>> rhd || || || 1
-   N01 805 71    N01 805 71 qty: || || || || *
hose in coils of 5m'order unit 5'for recirculated air operationpossibility F >> 70-W-095 695
  hose in coils of 5m'order unit 5'for recirculated air operationpossibility F >> 70-W-095 695 2, 5X1, 75 || || || || *
30 qty: 1
shorten to:
shorten to: 150MM 1
30A qty: 1
shorten to:
shorten to: 1070MM 1
30B qty: 1
shorten to:
shorten to: 50MM 1
-   N01 805 71    N01 805 71 qty: || || || || *
hose in coils of 5m'order unit 5'for recirculated air operationpossibility F 70-W-095 696>>
  hose in coils of 5m'order unit 5'for recirculated air operationpossibility F 70-W-095 696>> lhd
2, 5X1, 75
|| || || || *
30A qty: 1
shorten to:
shorten to: 1070MM 1
-   N01 805 71    N01 805 71 qty: || || || || *
hose in coils of 5m'order unit 5'for recirculated air operationpossibility F 70-W-095 696>>
  hose in coils of 5m'order unit 5'for recirculated air operationpossibility F 70-W-095 696>> rhd
2, 5X1, 75
|| || || || *
30 qty: 1
shorten to:
shorten to: 150MM 1
30A qty: 1
shorten to:
shorten to: 1070MM 1
30B qty: 1
shorten to:
shorten to: 50MM 1
31   191 820 677 B    191 820 677 B qty: || || || 1
Vacuum unitfor recirculated air operationpossibility F >> 70-W-095 695
  Vacuum unitfor recirculated air operationpossibility F >> 70-W-095 695 || || || 1
(31)   7D1 820 625    7D1 820 625 qty: || || || 1
Vacuum unitfor recirculated air operationpossibility F 70-W-095 696>>
  Vacuum unitfor recirculated air operationpossibility F 70-W-095 696>> lhd || || || 1
31   191 820 677 B    191 820 677 B qty: || || || 1
Vacuum unitfor recirculated air operationpossibility F 70-W-095 696>>
  Vacuum unitfor recirculated air operationpossibility F 70-W-095 696>> rhd || || || 1
32   N01 020 44    N01 020 44 qty: 2
Hexagon boltfor recirculated air operationpossibility
  Hexagon boltfor recirculated air operationpossibility M4X10 2
33   191 820 129    191 820 129 Sealfor recirculated air operationpossibility
  Sealfor recirculated air operationpossibility 550X12X6
34   N10 080 102    N10 080 102 qty: 3
Socket head bolt with hexagonsocket head (combination)for recirculated air operationpossibility
  Socket head bolt with hexagonsocket head (combination)for recirculated air operationpossibility M6X25 3
35   701 815 501    701 815 501 qty: 1
Vent trim for models with wheelbase:
  Vent trim for models with wheelbase: left
2920MM
1
(35)   701 815 502    701 815 502 qty: 1
Vent trim for models with wheelbase:
  Vent trim for models with wheelbase: right
2920MM
1
36   N01 166 44    N01 166 44 qty: 8
Washer
  Washer B4, 3X12X1 8
37   N90 641 801    N90 641 801 qty: 8
Washer
  Washer 3, 1X12X1, 4 8
38   N90 499 802    N90 499 802 qty: 8
Pan head bolt with doublethread
  Pan head bolt with doublethread 4X8 8
39   N01 396 81    N01 396 81 qty: 2
oval head panel screw
  oval head panel screw 4, 8X13 2
40   7D0 819 036    7D0 819 036 qty: || || || 1
chokefor recirculated air operationpossibility F >> 70-W-095 695
  chokefor recirculated air operationpossibility F >> 70-W-095 695 || || || 1
40   7D0 819 036    7D0 819 036 qty: || || || 1
chokefor recirculated air operationpossibility F 70-W-095 696>>
  chokefor recirculated air operationpossibility F 70-W-095 696>> rhd || || || 1
41   701 959 263    701 959 263 qty: 1
series resistance for freshair and hot air blower
  series resistance for freshair and hot air blower 1, 7/0, 8/0, 4 1