Fasteners D - 25.05.2009>> - 31.05.2010 - Tiguan(TIG) [EUROPA 2010 year]

Fasteners<br> D - 25.05.2009>> - 31.05.2010  - Tiguan - tig
part number information description remark unit model
Control unit (BCM) forconv. system & OB power supplyDiagnosis interface fordata bus (Gateway) D - 25.05.2009>>
- 31.05.2010

Control unit (BCM) forconv. system & OB power supplyDiagnosis interface fordata bus (Gateway) D - 25.05.2009>>
- 31.05.2010
Control unit (BCM) forconv. system & OB power supply D - 25.05.2009>>
- 31.05.2010

Control unit (BCM) forconv. system & OB power supply D - 25.05.2009>>
- 31.05.2010
1   5K0 937 087 D    5K0 937 087 D qty: 1
Control unit (BCM) forconv. system & OB power supply also to be used for: D >> - 02.11.2009
  Control unit (BCM) forconv. system & OB power supply also to be used for: D >> - 02.11.2009 433MHZ 5K0 937 084 5K0 937 086 1
(1)   5K0 937 087 D    5K0 937 087 D qty: 1
Control unit (BCM) forconv. system & OB power supply also to be used for: D - 02.11.2009>>
  Control unit (BCM) forconv. system & OB power supply also to be used for: D - 02.11.2009>> 433MHZ 5K0 937 084 B 5K0 937 086 C 1
  5K0 937 087 D Z76   5K0 937 087 D Z76 Control unit (BCM) forconv. system & OB power supply
PR:8K0,8K8+ 9M0
  Control unit (BCM) forconv. system & OB power supply PR:8K0,8K8+ 9M0
  5K0 937 087 D Z77   5K0 937 087 D Z77 Control unit (BCM) forconv. system & OB power supply
PR:9M0
  Control unit (BCM) forconv. system & OB power supply PR:9M0
  5K0 937 087 D Z78   5K0 937 087 D Z78 Control unit (BCM) forconv. system & OB power supply
PR:8K0,8K8+ 9M5,9M9
  Control unit (BCM) forconv. system & OB power supply PR:8K0,8K8+ 9M5,9M9
  5K0 937 087 D Z79   5K0 937 087 D Z79 Control unit (BCM) forconv. system & OB power supply
PR:9M5,9M9
  Control unit (BCM) forconv. system & OB power supply PR:9M5,9M9
(1)   5K0 937 087 B    5K0 937 087 B qty: 1
Control unit (BCM) forconv. system & OB power supply also to be used for: D >> - 02.11.2009
  Control unit (BCM) forconv. system & OB power supply also to be used for: D >> - 02.11.2009 315MHZ 5K0 937 084 A 5K0 937 086 B 1
(1)   5K0 937 087 F    5K0 937 087 F qty: 1
Control unit (BCM) forconv. system & OB power supply also to be used for: D - 02.11.2009>>
  Control unit (BCM) forconv. system & OB power supply also to be used for: D - 02.11.2009>> 315MHZ 5K0 937 084 C 5K0 937 086 E 1
  5K0 937 087 F Z75   5K0 937 087 F Z75 Control unit (BCM) forconv. system & OB power supply
PR:8K0,8K8+ 9M0
  Control unit (BCM) forconv. system & OB power supply PR:8K0,8K8+ 9M0
  5K0 937 087 F Z76   5K0 937 087 F Z76 Control unit (BCM) forconv. system & OB power supply
PR:9M0
  Control unit (BCM) forconv. system & OB power supply PR:9M0
  5K0 937 087 F Z77   5K0 937 087 F Z77 Control unit (BCM) forconv. system & OB power supply
PR:8K0,8K8+ 9M5,9M9
  Control unit (BCM) forconv. system & OB power supply PR:8K0,8K8+ 9M5,9M9
  5K0 937 087 F Z78   5K0 937 087 F Z78 Control unit (BCM) forconv. system & OB power supply
PR:9M5,9M9
  Control unit (BCM) forconv. system & OB power supply PR:9M5,9M9
(1)   5K0 937 087 G    5K0 937 087 G qty: 1
Control unit (BCM) forconv. system & OB power supply also to be used for: D >> - 02.11.2009
PR:7K4
  Control unit (BCM) forconv. system & OB power supply also to be used for: D >> - 02.11.2009 315MHZ 5K0 937 085 B 5K0 937 085 C 1 PR:7K4
(1)   5K0 937 087 G    5K0 937 087 G qty: 1
Control unit (BCM) forconv. system & OB power supply also to be used for: D - 02.11.2009>>
PR:7K4
  Control unit (BCM) forconv. system & OB power supply also to be used for: D - 02.11.2009>> 315MHZ 5K0 937 085 F 5K0 937 085 G 1 PR:7K4
  5K0 937 087 G Z6J   5K0 937 087 G Z6J Control unit (BCM) forconv. system & OB power supply
PR:8K0,8K8+ 9M0
  Control unit (BCM) forconv. system & OB power supply PR:8K0,8K8+ 9M0
  5K0 937 087 G Z6K   5K0 937 087 G Z6K Control unit (BCM) forconv. system & OB power supply
PR:9M0
  Control unit (BCM) forconv. system & OB power supply PR:9M0
  5K0 937 087 G Z6L   5K0 937 087 G Z6L Control unit (BCM) forconv. system & OB power supply
PR:8K0,8K8+ 9M5,9M9
  Control unit (BCM) forconv. system & OB power supply PR:8K0,8K8+ 9M5,9M9
  5K0 937 087 G Z6M   5K0 937 087 G Z6M Control unit (BCM) forconv. system & OB power supply
PR:9M5,9M9
  Control unit (BCM) forconv. system & OB power supply PR:9M5,9M9
Diagnosis interface fordata bus (Gateway) D - 25.05.2009>> - 02.11.2009
Diagnosis interface fordata bus (Gateway) D - 25.05.2009>> - 02.11.2009
(3)   7N0 907 530 A F   7N0 907 530 A F qty: 1
Diagnosis interface fordata bus (Gateway)
PR:3FA
  Diagnosis interface fordata bus (Gateway) 1 PR:3FA
(3)   7N0 907 530 A J   7N0 907 530 A J qty: 1
Diagnosis interface fordata bus (Gateway)
PR:3FU
  Diagnosis interface fordata bus (Gateway) 1 PR:3FU
Diagnosis interface fordata bus (Gateway) D - 02.11.2009>> - 31.05.2010
Diagnosis interface fordata bus (Gateway) D - 02.11.2009>> - 31.05.2010
(3)   7N0 907 530 A J   7N0 907 530 A J qty: 1
Diagnosis interface fordata bus (Gateway)
  Diagnosis interface fordata bus (Gateway) 1
  7N0 907 530 A JZ00   7N0 907 530 A JZ00 Diagnosis interface fordata bus (Gateway)
  Diagnosis interface fordata bus (Gateway)
Fasteners D - 25.05.2009>> - 31.05.2010
Fasteners D - 25.05.2009>> - 31.05.2010
5   5N1 959 503 B    5N1 959 503 B qty: 1
Retainer for control unit
  Retainer for control unit lhd 1
(5)   1K2 971 262 Q    1K2 971 262 Q qty: 1
Retainer for control unit
  Retainer for control unit rhd 1
10   N10 684 701    N10 684 701 qty: 2
Oval hexagon socket head bolt
  Oval hexagon socket head bolt M5X20 2