| | | | Coolant regulator housingCoolant regulatorthermal switch | | Coolant regulator housingCoolant regulatorthermal switch | 1.2/1.4 ltr.1.6ltr. | | |
| | | | Coolant regulator housingCoolant regulatorthermal switch 4-cylinder+ BBZ,BKY,BUD | | Coolant regulator housingCoolant regulatorthermal switch | 1.4ltr. | | 4-cylinder+ BBZ,BKY,BUD |
| | (1) | 032 121 111 A P | 032 121 111 A P qty: 1 Coolant regulator housing BBZ,BKY | | Coolant regulator housing | FA.HIMMERMANN | 1 | BBZ,BKY |
| | (1) | 032 121 111 C G | 032 121 111 C G qty: 1 Coolant regulator housing BUD | | Coolant regulator housing | FA.HIMMERMANN | 1 | BUD |
| | (1) | 032 121 111 B M | 032 121 111 B M qty: 1 Coolant regulator housing BUD | | Coolant regulator housing | FA.HENSCHEL | 1 | BUD |
| | (3) | N10 117 405 | N10 117 405 qty: 3 Socket head bolt with hexagonsocket head (combination) | | Socket head bolt with hexagonsocket head (combination) | M6X30 | 3 | |
| | (4) | 032 121 121 K | 032 121 121 K qty: 1 || 1 cover for thermostat use if required: BBZ,BKY | | cover for thermostat use if required: | FA.HENSCHEL 032 121 110 B | 1 || 1 | BBZ,BKY |
| | (4) | 032 121 121 K | 032 121 121 K qty: 1 || 1 cover for thermostat use if required: BUD | | cover for thermostat use if required: | FA.HENSCHEL 032 121 110 B | 1 || 1 | BUD |
| | (4) | 032 121 121 G | 032 121 121 G qty: 1 || 1 cover for thermostat use if required: BBZ,BKY | | cover for thermostat use if required: | FA.HIMMERMANN 032 121 110 F | 1 || 1 | BBZ,BKY |
| | (4) | 032 121 121 G | 032 121 121 G qty: 1 || 1 cover for thermostat use if required: BUD | | cover for thermostat use if required: | FA.HIMMERMANN 032 121 110 F | 1 || 1 | BUD |
| | 5 | 032 121 110 B | 032 121 110 B qty: 1 || || 1 Coolant regulator use if required: BBZ,BKY | | Coolant regulator use if required: | 87C-102C FA.HENSCHEL 032 121 121 K | 1 || || 1 | BBZ,BKY |
| | 5 | 032 121 110 B | 032 121 110 B qty: 1 || || 1 Coolant regulator use if required: BUD | | Coolant regulator use if required: | 87C-102C FA.HENSCHEL 032 121 121 K | 1 || || 1 | BUD |
| | (5) | 032 121 110 F | 032 121 110 F qty: 1 || || 1 Coolant regulator use if required: BBZ,BKY | | Coolant regulator use if required: | 83C-98C FA.HIMMERMANN 032 121 121 G | 1 || || 1 | BBZ,BKY |
| | (5) | 032 121 110 F | 032 121 110 F qty: 1 || || 1 Coolant regulator use if required: BUD | | Coolant regulator use if required: | 83C-98C FA.HIMMERMANN 032 121 121 G | 1 || || 1 | BUD |
| | 6 | N90 629 803 | N90 629 803 qty: 2 hex.hd. thread cutting bolt | | hex.hd. thread cutting bolt | 7X20 | 2 | |
| | 7 | 032 121 119 H | 032 121 119 H qty: 2 O-ring | | O-ring | 48X4, 2 | 2 | |
| | 8 | 06A 919 501 A | 06A 919 501 A qty: 1 Coolant temperature senderfor coolant temperaturegauge | | Coolant temperature senderfor coolant temperaturegauge | 2 pin black 20MM | 1 | |
| | 9 | 032 121 142 | 032 121 142 qty: 2 retaining spring | | retaining spring | | 2 | |
| | 10 | 357 121 140 | 357 121 140 qty: 1 Bungs | | Bungs | | 1 | |
| | 11 | N90 316 801 | N90 316 801 qty: 2 O-ring | | O-ring | 19, 6X3, 65 | 2 | |
| | | | Coolant regulator housingCoolant regulatorthermal switch 3-cylinder+ BMD,BME,BBM, BZG | | Coolant regulator housingCoolant regulatorthermal switch | 1.2 Ltr. | | 3-cylinder+ BMD,BME,BBM, BZG |
| | 15 | 03C 121 111 B | 03C 121 111 B qty: 1 Coolant regulator housing | | Coolant regulator housing | | 1 | |
| | 16 | 03C 121 110 A | 03C 121 110 A qty: 1 Coolant regulator | | Coolant regulator | 87C°-102C° | 1 | |
| | 17 | 03C 121 119 C | 03C 121 119 C qty: 1 O-ring | | O-ring | 52, 5X4, 5 | 1 | |
| | 18 | 03C 121 119 D | 03C 121 119 D qty: 1 Seal | | Seal | | 1 | |
| | 19 | 03C 121 121 C | 03C 121 121 C qty: 1 cover for thermostat | | cover for thermostat | | 1 | |
| | 20 | 032 121 142 | 032 121 142 qty: 1 retaining spring | | retaining spring | | 1 | |
| | 21 | 06A 919 501 A | 06A 919 501 A qty: 1 Coolant temperature sender | | Coolant temperature sender | 2 pin | 1 | |
| | 22 | N10 302 403 | N10 302 403 qty: 4 Socket head bolt withinner multipoint head | | Socket head bolt withinner multipoint head | M6X25 | 4 | |
| | 23 | N10 473 401 | N10 473 401 qty: 3 Hexagon socket head panel bolt | | Hexagon socket head panel bolt | 6X20 | 3 | |
| | 24 | N90 316 801 | N90 316 801 qty: 1 O-ring | | O-ring | 19, 6X3, 65 | 1 | |
| | | | Coolant regulator housingCoolant regulatorthermal switch 4-cylinder+ AXU,BTS | | Coolant regulator housingCoolant regulatorthermal switch | 1.4/1.6 ltr. | | 4-cylinder+ AXU,BTS |
| | (27) | 03C 121 111 G | 03C 121 111 G qty: 1 Coolant regulator housing AXU | | Coolant regulator housing | | 1 | AXU |
| | (27) | 03C 121 026 M | 03C 121 026 M qty: 1 Coolant regulator housing contains:Coolant pipe see illustration, item: BTS | | Coolant regulator housing contains:Coolant pipe see illustration, item: | 03C 121 065 D 121-032, 5 | 1 | BTS |
| | 28 | 03C 121 110 A | 03C 121 110 A qty: 1 Coolant regulator AXU | | Coolant regulator | 87C°-102C° | 1 | AXU |
| | (28) | 03C 121 110 Q | 03C 121 110 Q qty: 1 Coolant regulator BTS | | Coolant regulator | 83C-98C | 1 | BTS |
| | 29 | 03C 121 119 C | 03C 121 119 C qty: 1 O-ring AXU,BTS | | O-ring | 52, 5X4, 5 | 1 | AXU,BTS |
| | 30 | 03C 121 121 C | 03C 121 121 C qty: 1 cover for thermostat AXU | | cover for thermostat | | 1 | AXU |
| | (30) | 03C 121 121 D | 03C 121 121 D qty: 1 cover for thermostat BTS | | cover for thermostat | | 1 | BTS |
| | 31 | 032 121 142 | 032 121 142 qty: 1 retaining spring | | retaining spring | | 1 | |
| | 32 | 06A 919 501 A | 06A 919 501 A qty: 1 Coolant temperature sender | | Coolant temperature sender | 2 pin | 1 | |
| | 33 | 03C 121 119 | 03C 121 119 qty: 1 O-ring AXU,BTS | | O-ring | 45X4 | 1 | AXU,BTS |
| | (34) | 03C 121 110 E | 03C 121 110 E qty: 1 Coolant regulator AXU | | Coolant regulator | 103°C-120°C | 1 | AXU |
| | (34) | 03C 121 110 A A | 03C 121 110 A A qty: 1 Coolant regulator BTS | | Coolant regulator | 87C -102C | 1 | BTS |
| | 35 | 03C 121 118 C | 03C 121 118 C qty: 1 cover for thermostat AXU | | cover for thermostat | | 1 | AXU |
| | (35) | 03C 121 118 D | 03C 121 118 D qty: 1 cover for thermostat BTS | | cover for thermostat | | 1 | BTS |
| | 36 | 03C 121 119 E | 03C 121 119 E qty: 1 Seal AXU,BTS | | Seal | | 1 | AXU,BTS |
| | 37 | N91 097 001 | N91 097 001 qty: 4 Hexagon socket flathead bolt BTS,AXU | | Hexagon socket flathead bolt | M6X30 | 4 | BTS,AXU |
| | 38 | N10 473 401 | N10 473 401 qty: 6 Hexagon socket head panel bolt AXU | | Hexagon socket head panel bolt | 6X20 | 6 | AXU |
| | (38) | N10 611 201 | N10 611 201 qty: 6 oval head panel screw BTS | | oval head panel screw | 6X22 | 6 | BTS |
| | 39 | N90 316 801 | N90 316 801 qty: 1 O-ring | | O-ring | 19, 6X3, 65 | 1 | |