Individual parts - Passat/Variant/Santana(PA) [EUROPA 2013 year]

Individual parts  - Passat/Variant/Santana - pa
part number information description remark unit model
Wiring set for electronicallyregulated air-conditioning
Wiring set for electronicallyregulated air-conditioning
Wiring set for electronicallyregulated air-conditioning
Wiring set for electronicallyregulated air-conditioning
1   561 971 566 B    561 971 566 B qty: 1
Wiring set for electronicallyregulated air-conditioning
PR:9AK
  Wiring set for electronicallyregulated air-conditioning lhd 1 PR:9AK
(1)   561 971 566 D    561 971 566 D qty: 1
Wiring set for electronicallyregulated air-conditioning
PR:KH6
  Wiring set for electronicallyregulated air-conditioning 1 PR:KH6
Individual parts
Individual parts
10   1J0 937 713 A    1J0 937 713 A qty: 1 || || 1
Flat contact housing withcontact locking mechanism use if required: only to be used for:Fan control
  Flat contact housing withcontact locking mechanism use if required: only to be used for:Fan control 3 pin
brown
Greylight-green
1 || || 1
(10)   1J0 937 714 A    1J0 937 714 A qty: 1 || || 1
Flat contact housing withcontact locking mechanism use if required: only to be used for:Fan control
  Flat contact housing withcontact locking mechanism use if required: only to be used for:Fan control 3 pin
brown
Greylight-green
1 || || 1
11 qty: X
Cable holderNot for this model
Cable holderNot for this model X
12   6Q0 971 838 C    6Q0 971 838 C qty: X
Cable tie with holder for weld pin:
  Cable tie with holder for weld pin: 5X200 5 X
13   1J0 971 972    1J0 971 972 qty: 1
flat connector housingTemperature sensor
  flat connector housingTemperature sensor 2 pinblack 1
14 Flat contact housingNot for this model
Flat contact housingNot for this model
15   6Q0 972 706    6Q0 972 706 qty: X || || || || 2 || 1 || 1 || || 1
Flat contact housing withcontact locking mechanismServomotorlever fortemperature regulating flapDefroster flapLever for air distributionfor recirculated air operationpossibility
  Flat contact housing withcontact locking mechanismServomotorlever fortemperature regulating flapDefroster flapLever for air distributionfor recirculated air operationpossibility 6 pinblue X || || || || 2 || 1 || 1 || || 1
16   1J0 972 785    1J0 972 785 qty: 1
Flat contact housing withcontact locking mechanismCentral wiring set
  Flat contact housing withcontact locking mechanismCentral wiring set 10 pin 1
17   1J0 972 923    1J0 972 923 qty: 1
Flat contact housing withcontact locking mechanismTemperature sensorevaporator
  Flat contact housing withcontact locking mechanismTemperature sensorevaporator 2 pin 1
18   1K0 972 928    1K0 972 928 qty: 1
Flat contact housing withcontact locking mechanismControl and display panelfor air-conditioning systemClimatronic
  Flat contact housing withcontact locking mechanismControl and display panelfor air-conditioning systemClimatronic 16 pinblack 1
19   1K0 972 928 A    1K0 972 928 A qty: 1
Flat contact housingControl and display panelfor air-conditioning systemClimatronic
  Flat contact housingControl and display panelfor air-conditioning systemClimatronic 16 pinbrown 1