| | | | Central electrics for enginebayPotential distributor | | Central electrics for enginebayPotential distributor | 6 cylinder | | |
| | | | Central electrics for enginebay | | Central electrics for enginebay | | | |
| | | | ------------------------------Main fuse socket see illustration:------------------------------ | | ------------------------------Main fuse socket see illustration:------------------------------ | 915-000 | | |
| | 1 | 3C0 937 125 | 3C0 937 125 qty: 1 Central electrics for enginebay D >> - 24.05.2009 | | Central electrics for enginebay D >> - 24.05.2009 | | 1 | |
| | (1) | 3C0 937 125 A | 3C0 937 125 A qty: 1 E box D - 25.05.2009>> | | E box D - 25.05.2009>> | | 1 | |
| | (1) | 1K0 937 124 Q | 1K0 937 124 Q qty: 1 Central electrics for enginebay AXZ,BLV,BWS | | Central electrics for enginebay | | 1 | AXZ,BLV,BWS |
| | 2 | 3C0 971 249 | 3C0 971 249 qty: 1 Jumper relay location: | | Jumper relay location: | 1 | 1 | |
| | (2) | 3B0 951 253 | 3B0 951 253 qty: 1 contact close relayValvegas tank Slot: CDGA | | contact close relayValvegas tank Slot: | J908 A1 | 1 | CDGA |
| | (2) | 7M0 951 253 A | 7M0 951 253 A qty: 1 contact close relay relay location/code no.: BSE,BSF | | contact close relay relay location/code no.: | 2/100 | 1 | BSE,BSF |
| | (2) | 191 906 383 C | 191 906 383 C qty: 1 contact close relayfor fuel pump relay location/code no.: AXZ,BWA,BLV, BPY,BWS, CCTA,CBFA, CAWB | | contact close relayfor fuel pump relay location/code no.: | 3/167 | 1 | AXZ,BWA,BLV, BPY,BWS, CCTA,CBFA, CAWB |
| | (2) | 1K0 906 381 | 1K0 906 381 qty: 1 contact close relay relay location/code no.: BSE,BSF | | contact close relay relay location/code no.: | 4/458 | 1 | BSE,BSF |
| | (2) | 4H0 951 253 | 4H0 951 253 qty: 1 Relay relay location/code no.: to be used for code no.: | | Relay relay location/code no.: to be used for code no.: | J271, J317 /644 100 | 1 | |
| | 3 | 1K0 907 361 B | 1K0 907 361 B qty: 1 bracket - relay plate/fuse box | | bracket - relay plate/fuse box | | 1 | |
| | 4 | 1K0 937 132 F | 1K0 937 132 F qty: 1 Coverfor fuse box/relay plate | | Coverfor fuse box/relay plate | | 1 | |
| | 8 | 1K0 937 700 B | 1K0 937 700 B qty: 1 Flat contact housing | | Flat contact housing | 40 pin | 1 | |
| | 9 | 1K0 937 701 B | 1K0 937 701 B qty: 1 Flat contact housing | | Flat contact housing | 26 pin | 1 | |
| | 10 | 1K0 971 848 N | 1K0 971 848 N qty: 1 Cable holder | | Cable holder | | 1 | |
| | 12 | N01 713 111 | N01 713 111 qty: X flat fuse 19/2x5 | | flat fuse 19/2x5 | 10A -red- | X | |
| | (12) | N01 713 112 | N01 713 112 qty: X flat fuse 19/2x5 | | flat fuse 19/2x5 | 15A -lt blue- | X | |
| | (12) | N01 713 123 | N01 713 123 qty: X flat fuse 19/2x5 | | flat fuse 19/2x5 | 20A -yellow- | X | |
| | (12) | N01 713 114 | N01 713 114 qty: X flat fuse 19/2x5 | | flat fuse 19/2x5 | 25A -cl.glass- | X | |
| | (12) | N01 713 124 | N01 713 124 qty: X flat fuse 19/2x5 | | flat fuse 19/2x5 | 30A-lt green- | X | |
| | (12) | N01 713 116 | N01 713 116 qty: X flat fuse 19/2x5 | | flat fuse 19/2x5 | 5A -lt brown- | X | |
| | 13 | N10 118 105 | N10 118 105 qty: X Hexagon collar nutself-locking | | Hexagon collar nutself-locking | M5 | X | |
| | 14 | N10 251 901 | N10 251 901 qty: X flat fuse 29/2x8 | | flat fuse 29/2x8 | 40A -orange- | X | |
| | (14) | N10 251 902 | N10 251 902 qty: X flat fuse 29/2x8 | | flat fuse 29/2x8 | 60A -lt blue- | X | |
| | (14) | N10 251 904 | N10 251 904 qty: X flat fuse 29/2x8 | | flat fuse 29/2x8 | 50A -red- | X | |
| | 15 | N10 525 501 | N10 525 501 qty: X fuse | | fuse | 40A -green- | X | |
| | (15) | N10 525 502 | N10 525 502 qty: X fuse | | fuse | 50A -red- | X | |
| | (15) | N10 525 503 | N10 525 503 qty: X fuse | | fuse | 60A-GELB- | X | |
| | (15) | N10 525 504 | N10 525 504 qty: X fuse | | fuse | 70A -brown- | X | |
| | (15) | N10 525 505 | N10 525 505 qty: X fuse | | fuse | 80A -white- | X | |
| | (15) | N10 525 506 | N10 525 506 qty: X fuse | | fuse | 100A -blue- | X | |
| | (15) | N10 525 507 | N10 525 507 qty: X fuse | | fuse | 125A -pink- | X | |
| | (15) | N10 525 508 | N10 525 508 qty: X fuse | | fuse | 150A -grey- | X | |
| | (15) | N10 525 510 | N10 525 510 qty: X fuse | | fuse | 200A -violet- | X | |
| | (15) | 3C0 937 091 | 3C0 937 091 qty: 1 contact bridge | | contact bridge | | 1 | |
| | 15A | 3C0 937 629 B | 3C0 937 629 B qty: X Multi-fuse | | Multi-fuse | 150A | X | |
| | 15A | 3C0 937 629 C | 3C0 937 629 C qty: X Multi-fuse | | Multi-fuse | 180A | X | |
| | 16 | WHT 000 906 | WHT 000 906 qty: X shouldered bolt | | shouldered bolt | M5X13, 5 | X | |
| | 17 | 3B0 951 253 | 3B0 951 253 qty: 1 contact close relayFor vehicles with heatedwindscreen | | contact close relayFor vehicles with heatedwindscreen | | 1 | |
| | (17) | 038 907 281 B | 038 907 281 B qty: 1 Control unit for glow plug diesel eng. | | Control unit for glow plug | | 1 | diesel eng. |
| | 18 | 1K0 937 540 B | 1K0 937 540 B qty: 1 Retainer for relay | | Retainer for relay | | 1 | |
| | 19 | N90 767 602 | N90 767 602 qty: 2 Hexagon socket head panel bolt | | Hexagon socket head panel bolt | 6X12 | 2 | |
| | 19A | N01 508 213 | N01 508 213 qty: 2 Hexagon collar nut | | Hexagon collar nut | M6 | 2 | |
| | | | relay plate and relays============================== | | relay plate and relays============================== | | | |
| | 5 | 1K0 937 311 B | 1K0 937 311 B qty: 1 Coverrelay plate | | Coverrelay plate | | 1 | |
| | 6 | 1K0 937 507 B | 1K0 937 507 B qty: 1 relay plate | | relay plate | | 1 | |
| | 7 | 4H0 951 253 A | 4H0 951 253 A qty: 1 Relayrelay - starter relay location/code no.: to be used for code no.: | | Relayrelay - starter relay location/code no.: to be used for code no.: | J906 1/645 643 | 1 | |
| | (7) | 038 907 281 B | 038 907 281 B qty: 1 Control unit for glow plug relay location/code no.: | | Control unit for glow plug relay location/code no.: | J179 2/457 | 1 | |
| | (7) | 4H0 951 253 A | 4H0 951 253 A qty: 1 Relayfor additional heater relay location/code no.: to be used for code no.: | | Relayfor additional heater relay location/code no.: to be used for code no.: | 1st stage 4/645 53 | 1 | |
| | (7) | 4H0 951 253 | 4H0 951 253 qty: 1 Relayfor additional heater relay location/code no.: to be used for code no.: | | Relayfor additional heater relay location/code no.: to be used for code no.: | 2nd stage 5/644 100/370 | 1 | |
| | (7) | 6Q0 951 253 | 6Q0 951 253 qty: 1 Relayrelay - starter relay location/code no.: | | Relayrelay - starter relay location/code no.: | J907 6/489 | 1 | |
| | 11 | 1K0 971 910 B | 1K0 971 910 B qty: 1 Grommet | | Grommet | | 1 | |
| | | | Potential distributor 6-cylinder | | Potential distributor | | | 6-cylinder |
| | 20 | 1K0 937 517 | 1K0 937 517 qty: 1 Potential distributorSlave start socket | | Potential distributorSlave start socket | 2 point | 1 | |
| | 20A | 1K0 937 565 A | 1K0 937 565 A qty: 1 Cover cap | | Cover cap | | 1 | |
| | 21 | 1K0 972 591 | 1K0 972 591 qty: 1 Retaining plate | | Retaining plate | | 1 | |
| | 22 | N90 814 402 | N90 814 402 qty: 2 Blind rivet stud | | Blind rivet stud | M6X14/0, 5-1 | 2 | |
| | 23 | N02 300 213 | N02 300 213 qty: 2 hexagon nut, self-locking | | hexagon nut, self-locking | M6 | 2 | |
| | 24 | N10 005 306 | N10 005 306 qty: 1 hexagon head bolt (combi) | | hexagon head bolt (combi) | M6X12 | 1 | |