| | | | Wiring set section forengine compartment Diesel eng.+ CBDB,CEGA, CBDA | | Wiring set section forengine compartment | 2.0 Ltr. | | Diesel eng.+ CBDB,CEGA, CBDA |
| | | | Wiring set section forengine compartment The part number must be ordered manually by indicating the vehicle ID number Diesel eng.+ CBDB,CEGA, CBDA,CLCA | | Wiring set section forengine compartment The part number must be ordered manually by indicating the vehicle ID number | | | Diesel eng.+ CBDB,CEGA, CBDA,CLCA |
| | (1) | 1K5 970 923 | 1K5 970 923 qty: || || || 1 Wiring set section forengine compartment6-speed manual transmission F 1K-9-091 376>> 1K-9-299 000
| | Wiring set section forengine compartment6-speed manual transmission F 1K-9-091 376>> 1K-9-299 000 | lhd | || || || 1 | |
| | (1) | 1K5 970 923 A B | 1K5 970 923 A B qty: || || || 1 Wiring set section forengine compartment6-speed manual transmission F 1K-A-000 001>>
| | Wiring set section forengine compartment6-speed manual transmission F 1K-A-000 001>> | lhd | || || || 1 | |
| | (1) | 1K5 970 923 B | 1K5 970 923 B qty: || || || 1 Wiring set section forengine compartment6-speed manual transmission F 1K-9-091 376>> 1K-9-299 000
| | Wiring set section forengine compartment6-speed manual transmission F 1K-9-091 376>> 1K-9-299 000 | lhd | || || || 1 | |
| | (1) | 1K5 970 923 A D | 1K5 970 923 A D qty: || || || 1 Wiring set section forengine compartment6-speed manual transmission F 1K-A-000 001>>
| | Wiring set section forengine compartment6-speed manual transmission F 1K-A-000 001>> | lhd | || || || 1 | |
| | (1) | 1K5 970 923 A | 1K5 970 923 A qty: || || || 1 Wiring set section forengine compartment6-speed automatic gearbox F 1K-9-091 376>> 1K-9-299 000
| | Wiring set section forengine compartment6-speed automatic gearbox F 1K-9-091 376>> 1K-9-299 000 | lhd | || || || 1 | |
| | (1) | 1K5 970 923 A C | 1K5 970 923 A C qty: || || || 1 Wiring set section forengine compartment6-speed automatic gearbox F 1K-A-000 001>>
| | Wiring set section forengine compartment6-speed automatic gearbox F 1K-A-000 001>> | lhd | || || || 1 | |
| | (1) | 1K5 970 923 C | 1K5 970 923 C qty: || || || 1 Wiring set section forengine compartment6-speed automatic gearbox F 1K-9-091 376>> 1K-9-299 000
| | Wiring set section forengine compartment6-speed automatic gearbox F 1K-9-091 376>> 1K-9-299 000 | lhd | || || || 1 | |
| | (1) | 1K5 970 923 A L | 1K5 970 923 A L qty: || || || 1 Wiring set section forengine compartment6-speed automatic gearbox F 1K-A-000 001>>
| | Wiring set section forengine compartment6-speed automatic gearbox F 1K-A-000 001>> | lhd | || || || 1 | |
| | (1) | 1KM 970 923 | 1KM 970 923 qty: || || || 1 Wiring set section forengine compartment6-speed manual transmission F 1K-9-091 376>> 1K-9-299 000
| | Wiring set section forengine compartment6-speed manual transmission F 1K-9-091 376>> 1K-9-299 000 | rhd | || || || 1 | |
| | (1) | 1KM 970 923 A B | 1KM 970 923 A B qty: || || || 1 Wiring set section forengine compartment6-speed manual transmission F 1K-A-000 001>>
| | Wiring set section forengine compartment6-speed manual transmission F 1K-A-000 001>> | rhd | || || || 1 | |
| | (1) | 1KM 970 923 B H | 1KM 970 923 B H qty: 1 Wiring set section forengine compartment5-speed manual transmission D - 01.01.2010>> | | Wiring set section forengine compartment5-speed manual transmission D - 01.01.2010>> | | 1 | |
| | (1) | 1KM 970 923 B | 1KM 970 923 B qty: || || || 1 Wiring set section forengine compartment6-speed manual transmission F 1K-9-091 376>> 1K-9-299 000
| | Wiring set section forengine compartment6-speed manual transmission F 1K-9-091 376>> 1K-9-299 000 | rhd | || || || 1 | |
| | (1) | 1KM 970 923 A D | 1KM 970 923 A D qty: || || || 1 Wiring set section forengine compartment6-speed manual transmission F 1K-A-000 001>>
| | Wiring set section forengine compartment6-speed manual transmission F 1K-A-000 001>> | rhd | || || || 1 | |
| | (1) | 1KM 970 923 A | 1KM 970 923 A qty: || || || 1 Wiring set section forengine compartment6-speed automatic gearbox F 1K-9-091 376>> 1K-9-299 000
| | Wiring set section forengine compartment6-speed automatic gearbox F 1K-9-091 376>> 1K-9-299 000 | rhd | || || || 1 | |
| | (1) | 1KM 970 923 A C | 1KM 970 923 A C qty: || || || 1 Wiring set section forengine compartment6-speed automatic gearbox F 1K-A-000 001>>
| | Wiring set section forengine compartment6-speed automatic gearbox F 1K-A-000 001>> | rhd | || || || 1 | |
| | (1) | 1KM 970 923 C | 1KM 970 923 C qty: || || || 1 Wiring set section forengine compartment6-speed automatic gearbox F 1K-9-091 376>> 1K-9-299 000
| | Wiring set section forengine compartment6-speed automatic gearbox F 1K-9-091 376>> 1K-9-299 000 | rhd | || || || 1 | |
| | (1) | 1KM 970 923 A L | 1KM 970 923 A L qty: || || || 1 Wiring set section forengine compartment6-speed automatic gearbox F 1K-A-000 001>>
| | Wiring set section forengine compartment6-speed automatic gearbox F 1K-A-000 001>> | rhd | || || || 1 | |
| | | | Individual parts============================== | | Individual parts============================== | | | |
| | | | Corrug. tubes, T-pieces, clips, holders, grommets, cable ties, insulating hose, wiring, single wires and seals see special catalogue: ELECTRICAL CONNECTING ELEMENTS | | Corrug. tubes, T-pieces, clips, holders, grommets, cable ties, insulating hose, wiring, single wires and seals see special catalogue: ELECTRICAL CONNECTING ELEMENTS | | | |
| | 2 | 1E0 971 921 | 1E0 971 921 qty: 1 Bracket protective cover | | Bracket protective cover | | 1 | |
| | 3 | N90 815 401 | N90 815 401 qty: 1 Junction | | Junction | 7, 5-4, 5-4, 5 | 1 | |
| | 4 | N90 681 901 | N90 681 901 qty: 1 corrugated pipe end piece | | corrugated pipe end piece | 4, 5 | 1 | |
| | 5 | 1J0 973 702 | 1J0 973 702 qty: 1 Flat contact housing withcontact locking mechanism | | Flat contact housing withcontact locking mechanism | 2 pinblack | 1 | |
| | 6 | 3C0 972 841 | 3C0 972 841 qty: X Bungs also to be used for: | | Bungs also to be used for: | orangenatural | X | |
| | 7 | 1J0 973 724 | 1J0 973 724 qty: 1 || X || X || X || X || X Flat contact housing Possible single wire: | | Flat contact housing Possible single wire: | 4 pin 000 979 133 000 979 133 A 000 979 133 AB 000 979 225 000 979 225 A | 1 || X || X || X || X || X | |
| | 8 | 357 972 841 | 357 972 841 qty: X Bungs | | Bungs | green | X | |
| | 9 | 8E0 971 921 | 8E0 971 921 qty: 1 Protective cap automatic | | Protective cap | | 1 | automatic |
| | 10 | 1J0 972 841 A | 1J0 972 841 A qty: X Bungs | | Bungs | white | X | |
| | 11 | 1J0 927 320 | 1J0 927 320 qty: 1 || || X || X Round connector housing withcontact locking mechanism Possible single wire: | | Round connector housing withcontact locking mechanism Possible single wire: | 20 pin 000 979 154 E 000 979 154 E | 1 || || X || X | |
| | 12 | 1J0 973 737 | 1J0 973 737 qty: 1 || || X || X || X Flat contact housing withcontact locking mechanism Possible single wire: 1,0 1,0 2,5 | | Flat contact housing withcontact locking mechanism Possible single wire: | 14 pin black 000 979 131 E 000 979 133 000 979 225 | 1 || || X || X || X | 1,0 1,0 2,5 |
| | 13 | N90 682 101 | N90 682 101 qty: 1 corrugated pipe end piece AES | | corrugated pipe end piece | 10 | 1 | AES |
| | 14 | 1J0 973 735 | 1J0 973 735 qty: 1 || || X || X || X || X || X Flat contact housing withcontact locking mechanism Possible single wire: 1,0 1,0 1,0 2,5 2,5 | | Flat contact housing withcontact locking mechanism Possible single wire: | 10 pin 000 979 131 E 000 979 133 000 979 133 A 000 979 225 000 979 225 A | 1 || || X || X || X || X || X | 1,0 1,0 1,0 2,5 2,5 |
| | (14) | 6R0 973 735 | 6R0 973 735 qty: 1 || X || X || X || X || X Flat contact housing Possible single wire: 1,0 1,0 1,0 2,5 2,5 | | Flat contact housing Possible single wire: | 10 pin 000 979 131 E 000 979 133 000 979 133 A 000 979 225 000 979 225 A | 1 || X || X || X || X || X | 1,0 1,0 1,0 2,5 2,5 |
| | 15 | 038 973 721 B | 038 973 721 B qty: 1 Flat contact housing withcontact locking mechanism Possible single wire: 1,0. 2,5 2,5 | | Flat contact housing withcontact locking mechanism Possible single wire: | 11 pin 000 979 133 000 979 225 000 979 227 | 1 | 1,0. 2,5 2,5 |
| | 16 | 1J0 972 844 | 1J0 972 844 qty: X Bungs | | Bungs | white | X | |
| | 17 | 1K0 937 700 B | 1K0 937 700 B qty: 1 || X || X || X || X || X || X Flat contact housing Possible single wire: 0,5 1,0 2,5 4,0 6,0 0,5 | | Flat contact housing Possible single wire: | 40 pin 000 979 025 000 979 150 EA 000 979 243 E 000 979 308 E 000 979 406 000 979 027 | 1 || X || X || X || X || X || X | 0,5 1,0 2,5 4,0 6,0 0,5 |
| | 18 | 8K0 973 705 | 8K0 973 705 qty: 1 || || X || X || X || X Flat contact housing withcontact locking mechanism Possible single wire: 0,5 0,5 1,0 1,0 | | Flat contact housing withcontact locking mechanism Possible single wire: | 5 pin black 000 979 025 000 979 025 EA 000 979 150 E 000 979 150 EA | 1 || || X || X || X || X | 0,5 0,5 1,0 1,0 |
| | 19 | 1K0 972 961 | 1K0 972 961 qty: 1 Flat contact housing withcontact locking mechanism Possible single wire: | | Flat contact housing withcontact locking mechanism Possible single wire: | 16 pin black 000 979 009 000 979 009 EA 000 979 026 E 000 979 026 EA | 1 | |
| | 20 | 1K0 972 924 | 1K0 972 924 qty: 1 || || X || X || X || X Flat contact housing withcontact locking mechanism Possible single wire: | | Flat contact housing withcontact locking mechanism Possible single wire: | 8 pin black 000 979 026 E 000 979 026 EA 000 979 242 000 979 009 | 1 || || X || X || X || X | |
| | 21 | 1J0 973 713 | 1J0 973 713 qty: 1 || || X || X Flat contact housing Possible single wire: 1,0 1,0 | | Flat contact housing Possible single wire: | 6 pin black 000 979 131 E 000 979 131 EA | 1 || || X || X | 1,0 1,0 |
| | 22 | 8K0 973 702 A | 8K0 973 702 A qty: 1 || || X || X || X || X Flat contact housing withcontact locking mechanism Possible single wire: 0,5 0,5 1,0 1,0 | | Flat contact housing withcontact locking mechanism Possible single wire: | 2 pin brown 000 979 025 000 979 025 EA 000 979 150 EA 000 979 150 EA | 1 || || X || X || X || X | 0,5 0,5 1,0 1,0 |
| | 23 | 8K0 973 702 C | 8K0 973 702 C qty: 1 || || X || X || X || X Flat contact housing withcontact locking mechanism Possible single wire: 0,5 0,5 1,0 1,0 | | Flat contact housing withcontact locking mechanism Possible single wire: | 2 pin orange 000 979 025 000 979 025 EA 000 979 150 EA 000 979 150 EA | 1 || || X || X || X || X | 0,5 0,5 1,0 1,0 |
| | 24 | 4B0 973 712 | 4B0 973 712 qty: 1 || || X || X Flat contact housing withcontact locking mechanism Possible single wire: | | Flat contact housing withcontact locking mechanism Possible single wire: | 4 pin 000 979 131 E 000 979 131 EA | 1 || || X || X | |
| | 25 | N10 478 501 | N10 478 501 qty: X Retainer, swivel for cable:(Clamp base, rotating) | | Retainer, swivel for cable:(Clamp base, rotating) | 10MM + 5, 0MM | X | |
| | 26 | 7D0 971 921 A | 7D0 971 921 A qty: || 1 Protective cap F 1K-9-036 551>>
| | Protective cap F 1K-9-036 551>> | 4 pinblack | || 1 | |
| | 27 | 1J0 973 702 | 1J0 973 702 qty: 1 Flat contact housing withcontact locking mechanism | | Flat contact housing withcontact locking mechanism | 2 pinblack | 1 | |
| | 28 | 4B0 971 848 | 4B0 971 848 qty: X Bundling clip f wiring harness For hole/material thickness: | | Bundling clip f wiring harness For hole/material thickness: | 6, 5 / 0, 6-3 | X | |
| | 29 | 1J0 973 722 | 1J0 973 722 qty: 1 Flat contact housing withcontact locking mechanism | | Flat contact housing withcontact locking mechanism | 2 pinblack | 1 | |
| | 30 | 3D0 971 838 A | 3D0 971 838 A qty: 1 Cable tie with holder for weld pin: | | Cable tie with holder for weld pin: | | 1 | |
| | 31 | 1K0 973 751 | 1K0 973 751 qty: 1 || || X flat contact housing withgasket Possible single wire: | | flat contact housing withgasket Possible single wire: | 1 pin black 000 979 243 E | 1 || || X | |
| | 32 | N90 937 702 | N90 937 702 qty: X Cable tiestoothed quadrant | | Cable tiestoothed quadrant | outer | X | |
| | 33 | 3C0 906 385 | 3C0 906 385 qty: 1 || || X || X Flat contact housing withcontact locking mechanism Possible single wire: | | Flat contact housing withcontact locking mechanism Possible single wire: | 94-pin 000 979 030E 000 979 242 | 1 || || X || X | |
| | 34 | 7L0 971 904 A | 7L0 971 904 A qty: X Sealing pin | | Sealing pin | 0, 63 MM | X | |
| | 35 | 7L0 971 904 | 7L0 971 904 qty: X Sealing pin | | Sealing pin | 1, 5 MM | X | |
| | 36 | 443 937 527 | 443 937 527 qty: X || X || X || X || X || X || X relay plate Possible single wire: 1,0 1,0 1,0 1,0 2,5 2,5 | | relay plate Possible single wire: | 9 pin 000 979 114 000 979 126 000 979 126 A 000 979 127 000 979 212 000 979 217 | X || X || X || X || X || X || X | 1,0 1,0 1,0 1,0 2,5 2,5 |
| | 37 | 8E0 937 527 | 8E0 937 527 qty: 1 || || X || X Adapterdual small relay plate Possible single wire: | | Adapterdual small relay plate Possible single wire: | 10 pin black 000 979 133 000 979 236 E | 1 || || X || X | |
| | 38 | 1K0 971 975 | 1K0 971 975 qty: 1 Flat contact housing withcontact locking mechanism | | Flat contact housing withcontact locking mechanism | | 1 | |
| | 39 | 1K0 972 977 A | 1K0 972 977 A qty: 1 flat contact housing withcap | | flat contact housing withcap | | 1 | |
| | 40 | 1J0 973 722 | 1J0 973 722 qty: 1 Flat contact housing withcontact locking mechanism | | Flat contact housing withcontact locking mechanism | 2 pinblack | 1 | |
| | 41 | 1K0 973 706 | 1K0 973 706 qty: 1 || || X Flat contact housing withcontact locking mechanism Possible single wire: | | Flat contact housing withcontact locking mechanism Possible single wire: | 6 pin black 000 979 025 | 1 || || X | |
| | 42 | N10 532 201 | N10 532 201 qty: X Retainer, swivel for corrugated pipe: | | Retainer, swivel for corrugated pipe: | 14MM 7, 5MM | X | |
| | 43 | N90 682 001 | N90 682 001 qty: 1 corrugated pipe end piece | | corrugated pipe end piece | 7, 5 | 1 | |