Wiring set for battery and 3-phase alternatorEa... - Golf(GO) [EUROPA 1984 year]

Wiring set for battery<br>and 3-phase alternatorEarth line  - Golf - go
part number information description remark unit model
Wiring set for batteryand 3-phase alternatorEarth line
Wiring set for batteryand 3-phase alternatorEarth line
(1)   357 971 228 C    357 971 228 C qty: 1
Wiring set for battery +
manual
gearbox
  Wiring set for battery + 420MM 1 manual
gearbox
(1)   321 971 228 A    321 971 228 A qty: 1
Wiring set for battery +
  Wiring set for battery + 1
(2)   171 971 235 F    171 971 235 F qty: 1
Wiring set for battery -
  Wiring set for battery - 1
(2A) qty: 1
No longer available
manual
gearbox
No longer available 1.6-1.8 Ltr. 1 manual
gearbox
(2A)   171 971 349 A G   171 971 349 A G qty: 1
Wiring set for three-phasealternator
manual
gearbox
  Wiring set for three-phasealternator 1.6-1.8 Ltr. 1 manual
gearbox
(2A)   321 998 349    321 998 349 qty: 1
Wiring set for three-phasealternator
  Wiring set for three-phasealternator 1.05/1.3Ltr. 1
(2A)   171 971 349 A L   171 971 349 A L qty: 1
Wiring set for three-phasealternator
Manual
gearbox+
CARAT: T-DIESEL "J..":DIESEL T-DIESEL
  Wiring set for three-phasealternator 1 Manual
gearbox+
CARAT: T-DIESEL "J..":DIESEL T-DIESEL
(2A)   171 971 349 A N   171 971 349 A N qty: 1 || || 1
Wiring set for three-phasealternator use if required:
automatic
  Wiring set for three-phasealternator use if required: 161 971 990 A 1 || || 1 automatic
(2A)   191 971 349 A    191 971 349 A qty: 1
Wiring set for three-phasealternator
air condit./
Manual
gearbox+
DIESEL, T-DIESEL
  Wiring set for three-phasealternator 1 air condit./
Manual
gearbox+
DIESEL, T-DIESEL
(2A)   191 971 349 L    191 971 349 L qty: 1 || || 1 || 1 || 1
Wiring set for three-phasealternator use if required:
air condit.
  Wiring set for three-phasealternator use if required: 161 971 990 A 161 971 976 A 111 971 921 B 1 || || 1 || 1 || 1 air condit.
(2A)   191 971 349 L    191 971 349 L qty: 1 || || 1 || 1 || 1
Wiring set for three-phasealternator use if required:
  Wiring set for three-phasealternator use if required: 90A 161 971 990 A 161 971 976 A 111 971 921 B 1 || || 1 || 1 || 1
-   161 971 976 A    161 971 976 A qty: X
flat connector housing
  flat connector housing 1 pin X
3   N01 740 52    N01 740 52 qty: 2
square head bolt
  square head bolt M6X38 2
4   N01 100 624    N01 100 624 qty: 2
Hexagon nut
  Hexagon nut M6 2
5   321 971 356 A    321 971 356 A qty: 1
horn wiring for steering wheelcap
  horn wiring for steering wheelcap 1
(6)   357 971 537    357 971 537 qty: 1
Earth lineIgnition coil
  Earth lineIgnition coil 360MM 1
7   533 971 537    533 971 537 qty: 1
Earth lineBonnet
  Earth lineBonnet 1
8   N90 169 301    N90 169 301 qty: 2
Weld screw'Order quantity 100'
  Weld screw'Order quantity 100' M6X12 2
9   N01 152 423    N01 152 423 qty: 2
Washer
  Washer 6, 4X12, 5X1, 6 2
(9)   N01 167 016    N01 167 016 qty: X
Washer
  Washer 8, 4X24X2 X
10   N02 214 811    N02 214 811 qty: 2
hexagon nut, self-locking
  hexagon nut, self-locking M6 2
11   171 971 862    171 971 862 qty: 1
Cable holder
  Cable holder 1
13   171 903 845    171 903 845 qty: 1
Flat contact housing
  Flat contact housing 3 pin 1
14   161 971 990 A    161 971 990 A qty: 1
Flat contact housing
  Flat contact housing 6, 3 1
15   171 971 934    171 971 934 qty: 1
Flat contact housing
air condit.
  Flat contact housing 1 pin 1 air condit.
16   N02 062 01    N02 062 01 qty: 1
Clamp
  Clamp D1-13.0X15 1