| | | | Wiring set for electronicallyregulated air-conditioning | | Wiring set for electronicallyregulated air-conditioning | | | |
| | | | Wiring set for electronicallyregulated air-conditioning F >> 1J-3B152 792 F >> 1J-3D502 437 F >> 1J-3P394 281 F >> 1J-3U350 160 F >> 1J-3W561 215
| | Wiring set for electronicallyregulated air-conditioning F >> 1J-3B152 792 F >> 1J-3D502 437 F >> 1J-3P394 281 F >> 1J-3U350 160 F >> 1J-3W561 215 | | | |
| | (1) | 1J1 971 566 A K | 1J1 971 566 A K qty: 1 Wiring set for electronicallyregulated air-conditioning | | Wiring set for electronicallyregulated air-conditioning | lhd | 1 | |
| | (1) | 1J1 971 566 A N | 1J1 971 566 A N qty: 1 Wiring set for electronicallyregulated air-conditioningmapped cooling | | Wiring set for electronicallyregulated air-conditioningmapped cooling | lhd | 1 | |
| | (1) | 1J2 971 566 A K | 1J2 971 566 A K qty: 1 Wiring set for electronicallyregulated air-conditioning | | Wiring set for electronicallyregulated air-conditioning | rhd | 1 | |
| | (1) | 1J2 971 566 A N | 1J2 971 566 A N qty: 1 Wiring set for electronicallyregulated air-conditioningmapped cooling | | Wiring set for electronicallyregulated air-conditioningmapped cooling | rhd | 1 | |
| | | | Wiring set for electronicallyregulated air-conditioning F 1J-3B152 793>> F 1J-3D502 438>> F 1J-3P394 282>> F 1J-3U350 161>> F 1J-3W561 216>>
| | Wiring set for electronicallyregulated air-conditioning F 1J-3B152 793>> F 1J-3D502 438>> F 1J-3P394 282>> F 1J-3U350 161>> F 1J-3W561 216>> | | | |
| | (1) | 1J1 971 566 B C | 1J1 971 566 B C qty: 1 Wiring set for electronicallyregulated air-conditioning | | Wiring set for electronicallyregulated air-conditioning | lhd | 1 | |
| | (1) | 1J1 971 566 B D | 1J1 971 566 B D qty: 1 Wiring set for electronicallyregulated air-conditioningmapped cooling | | Wiring set for electronicallyregulated air-conditioningmapped cooling | lhd | 1 | |
| | (1) | 1J2 971 566 A P | 1J2 971 566 A P qty: 1 Wiring set for electronicallyregulated air-conditioning | | Wiring set for electronicallyregulated air-conditioning | rhd | 1 | |
| | (1) | 1J2 971 566 A Q | 1J2 971 566 A Q qty: 1 Wiring set for electronicallyregulated air-conditioningmapped cooling | | Wiring set for electronicallyregulated air-conditioningmapped cooling | rhd | 1 | |
| | | | Individual parts | | Individual parts | | | |
| | 3 | 1J0 959 971 | 1J0 959 971 qty: 1 Flat contact housingConnection pieceFan | | Flat contact housingConnection pieceFan | 2 pin | 1 | |
| | (3) | 1J0 972 752 | 1J0 972 752 qty: 1 Flat contact housingConnection pieceFan | | Flat contact housingConnection pieceFan | 2 pin | 1 | |
| | 3A | 1J1 971 843 | 1J1 971 843 qty: 1 Cable guideConnection piece | | Cable guideConnection piece | lhd | 1 | |
| | 3B | 1J2 971 843 A | 1J2 971 843 A qty: 1 Bracket | | Bracket | rhd | 1 | |
| | (3B) | 3D0 971 838 | 3D0 971 838 qty: 1 Cable tie with holder for plastic pin: | | Cable tie with holder for plastic pin: | 5X200 5 | 1 | |
| | (4) | 1J0 971 972 | 1J0 971 972 qty: 1 flat connector housingTemperature sensorVentmapped cooling | | flat connector housingTemperature sensorVentmapped cooling | 2 pin | 1 | |
| | 4 | 1J0 972 923 | 1J0 972 923 qty: 1 Flat contact housing withcontact locking mechanismConnection pieceTemperature sensorIntake air duct | | Flat contact housing withcontact locking mechanismConnection pieceTemperature sensorIntake air duct | 2 pin | 1 | |
| | (4A) | 3B0 972 702 | 3B0 972 702 qty: 1 Flat contact housing withcontact locking mechanismConnection pieceTemperature sensorFootwell vent | | Flat contact housing withcontact locking mechanismConnection pieceTemperature sensorFootwell vent | 2 pin | 1 | |
| | (5) | 1H0 972 702 A | 1H0 972 702 A qty: 1 Flat contact housingConnection pieceTemperature sensorFootwell vent | | Flat contact housingConnection pieceTemperature sensorFootwell vent | 2 pin | 1 | |
| | (5) | 3B0 972 705 | 3B0 972 705 qty: 1 Flat contact housingConnection pieceventilation flap | | Flat contact housingConnection pieceventilation flap | 5 pin | 1 | |
| | 5 | 535 972 705 | 535 972 705 qty: 1 Flat contact housingConnection pieceventilation flap | | Flat contact housingConnection pieceventilation flap | 5 pin | 1 | |
| | (6) | 6Q0 972 736 | 6Q0 972 736 qty: 1 Flat contact housing withcontact locking mechanismCoupling elementwiring harness for interior | | Flat contact housing withcontact locking mechanismCoupling elementwiring harness for interior | 12 pin | 1 | |
| | (6) | 6Q0 972 777 | 6Q0 972 777 qty: 1 Flat contact housing withcontact locking mechanismCoupling elementwiring harness for interior | | Flat contact housing withcontact locking mechanismCoupling elementwiring harness for interior | 17-pin | 1 | |
| | (6) | 6Q0 972 778 | 6Q0 972 778 qty: 1 Flat contact housing withcontact locking mechanismCoupling elementwiring harness for interior | | Flat contact housing withcontact locking mechanismCoupling elementwiring harness for interior | 17-pin | 1 | |
| | (7) | 1J0 972 752 | 1J0 972 752 qty: 1 Flat contact housingConnection pieceFan motor | | Flat contact housingConnection pieceFan motor | 2 pin | 1 | |
| | 7 | 1J0 972 753 | 1J0 972 753 qty: 1 Flat contact housingConnection pieceFan motor | | Flat contact housingConnection pieceFan motor | 3 pin | 1 | |
| | (9) | 1J0 972 753 | 1J0 972 753 qty: 1 Flat contact housingConnection pieceFan control | | Flat contact housingConnection pieceFan control | 3 pin | 1 | |
| | 9 | 4A0 972 883 | 4A0 972 883 qty: 1 Flat contact housing withcontact locking mechanismConnection pieceHeater with fresh air andheating control F >> 1J-3B152 792 F >> 1J-3D502 437 F >> 1J-3P394 281 F >> 1J-3U350 160 F >> 1J-3W561 215
| | Flat contact housing withcontact locking mechanismConnection pieceHeater with fresh air andheating control F >> 1J-3B152 792 F >> 1J-3D502 437 F >> 1J-3P394 281 F >> 1J-3U350 160 F >> 1J-3W561 215 | 12 pin | 1 | |
| | (9) | 8E0 972 112 | 8E0 972 112 qty: 1 Flat contact housing withcontact locking mechanismConnection pieceHeater with fresh air andheating control F 1J-3B152 793>> F 1J-3D502 438>> F 1J-3P394 282>> F 1J-3U350 161>> F 1J-3W561 216>>
0,5 0,5 | | Flat contact housing withcontact locking mechanismConnection pieceHeater with fresh air andheating control F 1J-3B152 793>> F 1J-3D502 438>> F 1J-3P394 282>> F 1J-3U350 161>> F 1J-3W561 216>> | 12 pinblack | 1 | 0,5 0,5 |
| | 10 | 4A0 972 883 A | 4A0 972 883 A qty: 1 Flat contact housing withcontact locking mechanismConnection piecefresh airand heater controls F >> 1J-3B152 792 F >> 1J-3D502 437 F >> 1J-3P394 281 F >> 1J-3U350 160 F >> 1J-3W561 215
| | Flat contact housing withcontact locking mechanismConnection piecefresh airand heater controls F >> 1J-3B152 792 F >> 1J-3D502 437 F >> 1J-3P394 281 F >> 1J-3U350 160 F >> 1J-3W561 215 | 16 pin | 1 | |
| | (10) | 8E0 972 416 | 8E0 972 416 qty: 1 Flat contact housing withcontact locking mechanismConnection piecefresh airand heater controls F 1J-3B152 793>> F 1J-3D502 438>> F 1J-3P394 282>> F 1J-3U350 161>> F 1J-3W561 216>>
| | Flat contact housing withcontact locking mechanismConnection piecefresh airand heater controls F 1J-3B152 793>> F 1J-3D502 438>> F 1J-3P394 282>> F 1J-3U350 161>> F 1J-3W561 216>> | 16 pinbrown | 1 | |
| | 11 | 4A0 972 883 B | 4A0 972 883 B qty: 1 Flat contact housing withcontact locking mechanismConnection piecefresh airand heater controls F >> 1J-3B152 792 F >> 1J-3D502 437 F >> 1J-3P394 281 F >> 1J-3U350 160 F >> 1J-3W561 215
| | Flat contact housing withcontact locking mechanismConnection piecefresh airand heater controls F >> 1J-3B152 792 F >> 1J-3D502 437 F >> 1J-3P394 281 F >> 1J-3U350 160 F >> 1J-3W561 215 | 20 pin | 1 | |
| | (11) | 8E0 972 420 A | 8E0 972 420 A qty: 1 Flat contact housingConnection piecefresh airand heater controls F 1J-3B152 793>> F 1J-3D502 438>> F 1J-3P394 282>> F 1J-3U350 161>> F 1J-3W561 216>>
| | Flat contact housingConnection piecefresh airand heater controls F 1J-3B152 793>> F 1J-3D502 438>> F 1J-3P394 282>> F 1J-3U350 161>> F 1J-3W561 216>> | 20 pinbrown | 1 | |
| | 12 | 4A0 972 883 C | 4A0 972 883 C qty: 1 Flat contact housing withcontact locking mechanismConnection piecefresh airand heater controls | | Flat contact housing withcontact locking mechanismConnection piecefresh airand heater controls | 16 pin | 1 | |
| | 14 | 1J0 972 785 | 1J0 972 785 qty: 1 Flat contact housing withcontact locking mechanismCoupling elementCentral wiring set | | Flat contact housing withcontact locking mechanismCoupling elementCentral wiring set | 10 pin | 1 | |
| | 16 | 7M0 973 119 | 7M0 973 119 qty: X || || 1 || 2 Flat contact housingConnection piececentral flap positioning motorServomotor F >> 1J-3B152 792 F >> 1J-3D502 437 F >> 1J-3P394 281 F >> 1J-3U350 160 F >> 1J-3W561 215
| | Flat contact housingConnection piececentral flap positioning motorServomotor F >> 1J-3B152 792 F >> 1J-3D502 437 F >> 1J-3P394 281 F >> 1J-3U350 160 F >> 1J-3W561 215 | 6 pinblack | X || || 1 || 2 | |
| | (16) | 6Q0 972 706 | 6Q0 972 706 qty: || || 1 || 2 Flat contact housing withcontact locking mechanismServomotorcentral flap positioning motor F 1J-3B152 793>> F 1J-3D502 438>> F 1J-3P394 282>> F 1J-3U350 161>> F 1J-3W561 216>>
| | Flat contact housing withcontact locking mechanismServomotorcentral flap positioning motor F 1J-3B152 793>> F 1J-3D502 438>> F 1J-3P394 282>> F 1J-3U350 161>> F 1J-3W561 216>> | 6 pinblue | || || 1 || 2 | |
| | 17 | 3D0 971 838 N | 3D0 971 838 N qty: X Cable ties with bracket For hole/material thickness: | | Cable ties with bracket For hole/material thickness: | 4, 5X200 6, 5 / 0, 3-3, 0 | X | |
| | (17) | 3D0 971 838 | 3D0 971 838 qty: X Cable tie with holder for plastic pin: | | Cable tie with holder for plastic pin: | 5X200 5 | X | |